カワムラ ヒデマサ   KAWAMURA Hidemasa
  河村 英将
   所属   埼玉医科大学  医学部 総合医療センター 放射線科(画像診断・核医学科、放射線腫瘍科)
   職種   教授
論文種別 学術雑誌(原著)
言語種別 英語
査読の有無 査読なし
表題 Dose-Volume Constraints for Thoracic, Abdominal, and Pelvic Carbon Ion Radiotherapy: A Literature Review.
掲載誌名 正式名:Cancer medicine
掲載区分国外
巻・号・頁 14(7),e70840頁
著者・共著者 Maria Varnava,Mutsumi Tashiro,Masahiko Okamoto,Ken Ando,Nobutero Kubo,Hidemasa Kawamura,Masahiro Onishi,Kei Shibuya,Takuya Kumazawa,Takeru Ohtaka,Tatsuya Ohno
発行年月 2025/04
概要 BACKGROUND: Applying dose-volume constraints is extremely important in ensuring the safe use of radiotherapy. However, constraints for carbon ion radiotherapy (CIRT) have not been established yet. This review aims to summarize dose-volume constraints for thoracic, abdominal, and pelvic CIRT that have been identified through previous research based on the Japanese models for relative biological effectiveness (RBE). RESULTS: Constraints are reported for the lungs, liver, stomach, gastrointestinal tract, rectum, sigmoid, bladder, nerves, rib, femoral head, sacrum, and skin. The constraints are classified into hard and soft to aid in determining whether priority should be given to the target coverage or organ-at-risk (OAR) sparing during treatment planning. CONCLUSIONS: Further research is necessary to verify the applicability of the reported constraints and to identify constraints for the OARs that have not been investigated yet.
DOI 10.1002/cam4.70840
PMID 40156204